Attic Furnace No Return Plenum

Can You Ventilate A Home With Attic Air

Can You Ventilate A Home With Attic Air

Wall Of Shame

Wall Of Shame

Bsi 109 How Changing Filters Led To A Condensation And Mold Problem Building Science Corporation

Bsi 109 How Changing Filters Led To A Condensation And Mold Problem Building Science Corporation

Return Air Registers Ducts For Heating Cooling Systems

Return Air Registers Ducts For Heating Cooling Systems

A New Cooling And Heating Equipment On Attic Floor Right To Left Download Scientific Diagram

A New Cooling And Heating Equipment On Attic Floor Right To Left Download Scientific Diagram

What Should You Do With The Ductboard Found In Your Hvac System

What Should You Do With The Ductboard Found In Your Hvac System

What Should You Do With The Ductboard Found In Your Hvac System

The return air plenum was a room with doors and banks of filters.

Attic furnace no return plenum.

No return air plenum. I have a huge concern about fire safety. If the space is conditioned it no longer is an attic and needs to be called conditioned space wiring within an area used as a plenum has to be in conduit. A 14 trunk too small emerges from the foundation wall in the basement in a roughly 2 2 notch at the top of the foundation wall.

How can and attic be held to the same standard as a plenum when its used for storage and water heaters and such. The major drawback is what material can go in your plenum. Ceiling space as a return air plenum. No radios or storage.

You ll also need to provide a return path from a basement air handler or main level return to the second floor. My mother has had me going up into her attic to seal the leaky ducts and parts of the plenum air handler that join up to the furnace and coil units. If there is no return duct the concept is that the attic space becomes a return air plenum and this is not uncommon in commercial plenums. Building cavities used as return air plenums is one of the leading causes of duct leakage in homes today.

The rating plate will state the max. Reality returns should be ducted with a small supply and return connected to the attic space. Not to mention that the air handler itself is in its own plenum. The sealed attic is great with return and supply duct inside of the thermal envelope of the building.

If you have a door at the top or bottom of the stairs you can replace with a louvered door. Cabling is not rated for plenum use. Tesp is typically measured using a manometer and a dwyer 303 static pressure tip inserted into the return plenum just before the filter and in the supply hopefully before the coil then add the two numbers disregarding signs. Otherwise this is a code violation.

Inspectors can learn how air leakage from ductwork may cause home energy loss increase utility bills lower comfort levels and make the hvac system less efficient. An attic is a space not a structural component the space cannot support anything but air. As long as there s an unobstructed path e g no door that can be closed the upstairs doesn t need a dedicated return. I think a cmp cable cost twice a non rated cable so my guess is all your communication fire alarm and misc.

Static pressure but it is usually 0 5 wci. Everything would need to be plenum rated including the low voltage cabling. I used to work in house at a 40 story high rise. As noted by one previous poster all materials in the attic must be plenum rated.

Info 801 What S Wrong With This Practice Using Unsealed Wall Cavities Or Panned Floor Joists As Return Plenum Building Science Corporation

Info 801 What S Wrong With This Practice Using Unsealed Wall Cavities Or Panned Floor Joists As Return Plenum Building Science Corporation

Ducted Returns Building America Solution Center

Ducted Returns Building America Solution Center

Why Is My Bedroom So Cold Carosella Design Build

Why Is My Bedroom So Cold Carosella Design Build

Hvac Talk Heating Air Refrigeration Discussion

Hvac Talk Heating Air Refrigeration Discussion

Source : pinterest.com